Trả lời mọi thắc mắc của bạn


Liệt kê những bài viết mới nhất

Bài viết mớiNgười viếtVào lúc
paltalk code HdAd
Sun Mar 06, 2016 1:28 am
vb ListView HdAd
Sun Mar 06, 2016 1:00 am
Find occurent of character in string nth HdAd
Sat Jan 16, 2016 10:48 pm
Send listbox items to textbox HdAd
Wed Jan 13, 2016 9:55 pm
[VB] Find word in listbox items HdAd
Wed Jan 13, 2016 7:55 pm
code cho hint2 HdAd
Wed Jan 13, 2016 3:22 pm
[vb] Font RTB HdAd
Tue Dec 29, 2015 10:29 am
[vb] selected text RTB HdAd
Tue Dec 29, 2015 9:06 am
[vb] send unicode text HdAd
Tue Dec 29, 2015 9:03 am
[vb] format multi richtextbox HdAd
Tue Dec 29, 2015 9:01 am
Trang web tai cac bang sang che HdAd
Mon Dec 28, 2015 1:28 pm
[VB] Sử dụng resource của chính chương trình HdAd
Sat Dec 26, 2015 8:56 pm
[vb] Phân biệt class và Module HdAd
Thu Dec 24, 2015 2:39 pm
[VB] MY API and Functions declaration HdAd
Mon Dec 21, 2015 1:45 pm
[vb] Khai báo và sử dụng hàm Setforeground HdAd
Mon Dec 21, 2015 1:29 pm
[VB] Sử dụng hàm Sendmessage để gửi tiếng việt, và format richtextbox HdAd
Mon Dec 21, 2015 1:26 pm
[VB] Find menu context handle/ID by SPY++ HdAd
Fri Dec 18, 2015 1:20 pm
[VB] Find menu context handle/ID - Vu Hai Ninh HdAd
Fri Dec 18, 2015 1:00 pm
[VB] Find menu context handle/ID HdAd
Fri Dec 18, 2015 12:54 pm
[VB] Sleep in VB program HdAd
Thu Dec 17, 2015 7:48 pm
[VB] CLose window if found HdAd
Wed Dec 16, 2015 7:07 pm
[VB] Không cho thay đổi kích cỡ form khi chạy HdAd
Wed Dec 16, 2015 3:28 pm
[VB] Không cho thay đổi text box khi chạy HdAd
Wed Dec 16, 2015 3:22 pm
[VB] Tìm cửa sổ và Button bằng FindWindow & FindWindowsEx HdAd
Wed Dec 16, 2015 3:16 pm
[VB] Xóa text mặc định của text box khi click HdAd
Wed Dec 16, 2015 3:12 pm


You are not connected. Please login or register

Ligation Protocol and notes

View previous topic View next topic Go down  Message [Page 1 of 1]

1 Ligation Protocol and notes on Tue Oct 20, 2015 1:28 pm

HdAd

avatar
Admin
Contents
1 General setup
2 Reaction time
3 Concentration and purification after ligation
4 References
General setup


250-500 ng vector
5-20x (in molar ratios) of insert--higher insert:vector ratio for shorter inserts
2 ul T4 DNA ligase buffer
1 ul DNA ligase
I have good luck using less ligase (say, 0.25uL per reaction). -Josh
Water to 20 ul total volume
For routine cloning, I also run ligations smaller than 20uL. I've never understood the reason to run a 20uL ligation, transform 1uL, and throw away the rest. 10uL is fine, and you use half as much ligase. You can go to 5uL if you want to push it. -Josh
Reaction time


According to NEB
At room temperature, use 1 ul of ligase in 20 ul rxn; 10 min for sticky end and 2 hrs for blunt end
At 16C, 1 U of enzyme can ligate 50% of HindIII fragments (at 300 ng/ul) in a 20 ul rxn in 30 min
Room temp, >10 min. I'm not aware of any reason that running longer is bad. I tend to run my ligations as long as is easily practical. -Josh


Room temp, 3 hrs (YC). I have tried transformation after a 20-min ligation and know that it yields fewer colonies than a 3-hr ligation. However, if you generally get more than enough colonies to screen, then the shorter ligation time may be sufficient.


16C, overnight (YC). I tried this as a last resort after multiple failures in cloning three constructs. One of the three constructs worked (and I'm not sure it's entirely due to the different ligation protocol), while the other two constructs showed no significant improvement (one went from no colony to 2 colonies; the other from 2 to 3 colonies).


I think overnight ligations are useful when you're doing tricky cloning. Blunt end, for example, or when you're cloning a library (and need lots of colonies). -Josh
Concentration and purification after ligation


In general, I do not purify or concentrate my ligation products. In the one instance where I did, I simply got 40 instead of 3 negative colonies, suggesting that I was concentrating a rare background product. However, it seems that other people in the lab have had good results using purified and/or concentrated ligation products. --YC


Concentration will concentrate everything - you get more positives and more negatives. So if your problem is too few colonies this will help. If the problem is a high background, you're better off redoing the digest/CIP/extraction process. -Josh


My point is that, in my experience, the cloning will either work or not work, and concentrating the ligation has not made a deference. I have noticed 2 main types of cloning failure. The first is that I get no colonies at all, and the effects of concentrating ligation products in this case has been described above. The second and more common situation is that I get a high background of negative colonies, such that I would have to screen through many of them to get a positive construct. In this case concentrating the ligation would also be ineffective, since one would obviously enrich both positive and negative colonies without improving the positive-to-negative ratio. This, of course, is just my personal experience. --YC


If you do wish to concentrate the ligation, make sure you either do phenol-chloroform extraction or use a column and not just concentrate with the speed vac.
If you're not cleaning up the ligation, it should be heat inactivated (65C for 10-20 minutes) before transformation[1]. -Josh


I actually never heat inactivate the ligation before transformation, but this is not a bad idea if you plan to keep the ligation product for potential repeats in transformation. --YC
lol!